Information about Cardiac Output
Cardiac output (CO) is the volume of blood being pumped by the heart, in particular by a ventricle in a minute.
When CO increases in a healthy but untrained individual, most of the increase can be attributed to an increase in HR. Change of posture, increased sympathetic nervous system activity, and decreased parasympathetic nervous system activity can also increase cardiac output. HR can vary by a factor of approximately 3, between 60 and 180 beats per minute, whilst SV can vary between 70 and 120 ml, a factor of only 1.7. [1][2][3]
A parameter related to SV is Ejection Fraction (EF). EF is the fraction of blood ejected by the Left Ventricle (LV) during the contraction or ejection phase of the cardiac cycle or Systole. Prior to the start of Systole, the LV is filled with blood to the capacity known as End Diastolic Volume (EDV) during the filling phase or diastole. During Systole, the LV contracts and ejects blood until it reaches its minimum capacity known as End Systolic Volume (ESV), it does not empty completely. Clearly the EF is dependent on the ventricular EDV which may vary with ventricular disease associated with ventricular dilatation. Even with LV dilatation and impaired contraction the CO may remain constant due to an increase in EDV.
Stroke Volume (SV) = EDV – ESV
Ejection Fraction (EF) = (SV / EDV) × 100%
Cardiac Output (CO) = SV × HR'''
Cardiac Index (CI) = CO / BSA = SV × HR/BSA
Diseases of the cardiovascular system are often associated with changes in CO, particularly the pandemic diseases of hypertension and heart failure. Cardiovascular disease can be associated with increased CO as occurs during infection and sepsis, or decreased CO, as in cardiomyopathy and heart failure. The ability to accurately measure CO is important in clinical medicine as it provides for improved diagnosis of abnormalities, and can be used to guide appropriate management. CO measurement, if it was accurate and non-invasive, would be adopted as part of every clinical examination from general observations to the intensive care ward, and would be as common as simple blood pressure measurements are now. Such practice, if it were adopted, may revolutionise the treatment of many cardiovascular diseases including hypertension and heart failure. This is the reason why CO measurement is now an important research and clinical focus in cardiovascular medicine.
There are a number of clinical methods for measurement of CO ranging from direct intracardiac catheterisation to non-invasive measurement of the arterial pulse. Each method has unique strengths and weaknesses and relative comparison is limited by the absence of a widely accepted “gold standard” measurement. CO can also be affected by the phase of respiration with intra-thoracic pressure changes influencing diastolic filling and therefore CO. This is important especially during mechanical ventilation, and CO should therefore be measured at a defined phase of the respiratory cycle (typically end-expiration).
VO2 = (CO x CA) - (CO x CV)
where CA = Oxygen concentration of arterial blood and CV = Oxygen concentration of venous blood. This allows us to say
CO = (VO2/CA - CV)*100
and therefore calculate CO. While considered to be the most accurate method for CO measurement Fick is invasive and requires time for the sample analysis, and accurate oxygen consumption samples are difficult to acquire. There have also been modifications to the Fick method where respiratory oxygen content is measured as part of a closed system and the consumed Oxygen calculated using an assumed oxygen consumption index which is then used to calculate CO. Other modifications use inert gas as tracers and measure the change in inspired and expired gas concentrations to calculate CO (Innacor, Innovision A/S, Denmark).
The trapezoid rule is often used as an approximation of this integral.
The PAC is balloon tipped and is inflated to occlude the pulmonary artery. The PAC thermodilution method involves injection of a small mount (10ml) of cold saline at a known temperature into the pulmonary artery and measuring the temperature a know distance away (6-10cm).
The CO can be calculated from the measured temperature curve (The “thermodilution curve”). High CO will change the temperature rapidly, and low CO will change the temperature slowly. Usually three or four repeated measures are averaged to improve accuracy. However it is complex to perform and there are many sources of inaccuracy in the method.[7][8] Modern catheters are fitted with a heating filament which intermittently heats and measures the thermodilution curve providing serial CO measurement.
PAC use is complicated by infection, Pulmonary artery rupture, cardiac tamponade, and air embolism. Recent studies suggest use of the PAC is both dangerous and expensive, and it may not improve patient survival or treatment.[4][5][6] PAC use is in decline as clinicians move to less invasive, more effective technologies for monitoring haemodynamics.
Physiologic or therapeutic changes in vessel diameter will be assumed to reflect changes in CO. Put simply PP methods measure the combined performance of the heart and the vessels thus limiting the application of PP methods for measurement of CO. This can be partially compensated for by intermittent calibration of the waveform to another CO measurement method and then monitoring the PP waveform. Ideally the PP waveform should be calibrated beat to beat.
There are invasive and non-invasive methods of measuring PP:
By resting a more sophisticated pressure sensing device, a tonometer, against the skin surface and sensing the pulsatile artery, continuous PP wave forms can be acquired non-invasively and analysis made of these pressure signals. Unfortunately the heart and vessels can function independently and sometimes paradoxically so that changes in the PP may both reflect and mask changes in CO. So these measures represent combined cardiac and vascular function only. Another similar system that uses the arterial pulse is the pressure recording analytical method (PRAM).
In the case of PiCCO, transpulmonary thermodilution is used as the calibrating technique. Transpulmonary thermodilution uses the Stewart-Hamilton principle, but measures temperatures changes from central venous line to a central arterial line (i.e. femoral or axillary) arterial line. The CO derived from this cold-saline thermodilution is used to calibrate the arterial PP contour, which can then provide continuous CO monitoring. The PiCCO algorithm is dependent on blood pressure waveform morphology (i.e. mathematical analysis of the PP waveform) and calculates continuous CO as described by Wesseling and co-workers.[9] Transpulmonary thermodilution spans right heart, pulmonary circulation and left heart; this allows further mathematical analysis of the thermodilution curve, giving measurements of cardiac filling volumes (GEDV), intrathoracic blood volume, and extravascular lung water. While transpulmonary thermodilution allows for less invasive CO calibration, the method is also less accurate than PA thermodilution and still requires a central venous and arterial line with the attendant infection risks.
In the case of LiDCO, the independent calibration technique is lithium dilution, again using the Stewart-Hamilton principle. Lithium dilution uses a peripheral vein to a peripheral arterial line; however, it does not provide information on cardiac filling volumes and extravascular lung water. Calibration measurements cannot be performed too frequently, and can be subject to error in the presence of certain muscle relaxants. The PulseCO algorithm used by LiDCO is based on pulse power derivation and is not dependent on waveform morphology.
This method requires recalibration if the patient moves or therapy to change the vessel tone (vaso-active therapy) is introduced. Additionally the safe storage and regulatory control of the Lithium Chloride may be problematic.
While the method is desirably non-invasive and inexpensive, it has not achieved the reliability and reproducibility required of a useful clinical tool, and the evolution of algorithms to convert impedance signals to CO across a variety of outputs and in a variety of diseases continues.
Velocity encoded MRI is based on detection of changes in the phase of proton precession. These changes are proportional to the velocity of the movement of those protons through a magnetic field with a known gradient. When using velocity encoded MRI, the result of the MRI scan is two sets of images for each time point in the cardiac cycle. One is an anatomical image and the other is an image where the signal intensity in each pixel is directly proportional to the through-plane velocity. The average velocity in a vessel, i.e. the aorta or the pulmonary artery, is hence quantified by measuring the average signal intensity of the pixels in the cross section of the vessel, and then multiplying by a known constant. The flow is calculated by multiplying the mean velocity by the cross-sectional area of the vessel. This flow data can be used to graph flow versus time. The area under the flow versus time curve for one cardiac cycle is the stroke volume. The length of the cardiac cycle is known and determines heart rate, and thereby CO can be calculated as the product of stroke volume and heart rate. MRI is typically used to quantify the flow over one cardiac cycle as the average of several heart beats, but it is also possible quantify the stroke volume in real time on a beat-for-beat basis[14].
While MRI is an important research tool for accurately measuring CO, it is currently not clinically used for hemodynamic monitoring in the emergency or intensive care setting. Cardiac output measurement by MRI is currently routinely used as a part of clinical cardiac MRI examinations[15].
This can be explained mathematically:
By simplifying D'arcy's Law, we get the equation that
When applied to the circulatory system, we get:
Where MAP = Mean Aortic (or Arterial) Blood Pressure in mmHg,
However, as MAP>>RAP, and RAP is approximately 0, this can be simplified to:
Physiologists will often re-arrange this equation, making MAP the subject, to study the body's responses.
As has already been stated, CO is also the product of the heart rate (HR) and the stroke volume (SV), which allows us to say:
Chronotropic effects (from chrono-, meaning time) are those that change the heart rate.
Chronotropic drugs may change the heart rate by affecting the nerves controlling the heart, or by changing the rhythm produced by the sinoatrial node.
..... Click the link for more information.
Normal Output
Cardiac output is equal to the stroke volume (SV) multiplied by the heart rate (HR). SV is the volume pumped per beat and the HR is the number of beats per minute. Therefore, if there are 70 beats per minute, and 70 ml blood is ejected with each beat, (SV), the cardiac output (CO) is 4900 ml/minute. This value is typical for an average adult at rest, although CO may reach up to 30 litres/minute during extreme exercise by elite athletes.Clinical Use
The function of the heart is to transport the blood to deliver oxygen, nutrients and chemicals to the cells of the body to ensure their survival and proper function and to remove the cellular wastes. CO indicates how well the heart is performing this function. CO is regulated principally by the demand for oxygen by the cells of the body. If the cells are working hard, with a high metabolic oxygen demand then the CO is raised to increase the supply of oxygen to the cells, while at rest when the cellular demand is low, the CO is said to be baseline. CO is regulated not only by the heart as it pumps, but also by the function of the vessels of the body as they actively relax and contract thereby increasing and decreasing the resistance to flow.When CO increases in a healthy but untrained individual, most of the increase can be attributed to an increase in HR. Change of posture, increased sympathetic nervous system activity, and decreased parasympathetic nervous system activity can also increase cardiac output. HR can vary by a factor of approximately 3, between 60 and 180 beats per minute, whilst SV can vary between 70 and 120 ml, a factor of only 1.7. [1][2][3]
A parameter related to SV is Ejection Fraction (EF). EF is the fraction of blood ejected by the Left Ventricle (LV) during the contraction or ejection phase of the cardiac cycle or Systole. Prior to the start of Systole, the LV is filled with blood to the capacity known as End Diastolic Volume (EDV) during the filling phase or diastole. During Systole, the LV contracts and ejects blood until it reaches its minimum capacity known as End Systolic Volume (ESV), it does not empty completely. Clearly the EF is dependent on the ventricular EDV which may vary with ventricular disease associated with ventricular dilatation. Even with LV dilatation and impaired contraction the CO may remain constant due to an increase in EDV.
Stroke Volume (SV) = EDV – ESV
Ejection Fraction (EF) = (SV / EDV) × 100%
Cardiac Output (CO) = SV × HR'''
Cardiac Index (CI) = CO / BSA = SV × HR/BSA
- HR is Heart Rate, expressed as BPM (Beats Per Minute)
- BSA is Body Surface Area in square metres.
Diseases of the cardiovascular system are often associated with changes in CO, particularly the pandemic diseases of hypertension and heart failure. Cardiovascular disease can be associated with increased CO as occurs during infection and sepsis, or decreased CO, as in cardiomyopathy and heart failure. The ability to accurately measure CO is important in clinical medicine as it provides for improved diagnosis of abnormalities, and can be used to guide appropriate management. CO measurement, if it was accurate and non-invasive, would be adopted as part of every clinical examination from general observations to the intensive care ward, and would be as common as simple blood pressure measurements are now. Such practice, if it were adopted, may revolutionise the treatment of many cardiovascular diseases including hypertension and heart failure. This is the reason why CO measurement is now an important research and clinical focus in cardiovascular medicine.
Measuring Cardiac Output
Circulation is a critical and variable function of human physiology and disease. An accurate and non-invasive measurement of CO is the holy grail of cardiovascular assessment. This would allow continuous monitoring of central circulation and provide improved insights into normal physiology, pathophysiology and treatments for disease. Invasive methods are well accepted, but there is increasing evidence that these methods are neither accurate nor effective in guiding therapy, so there is an increasing focus on development of non-invasive methods.[4][5][6]There are a number of clinical methods for measurement of CO ranging from direct intracardiac catheterisation to non-invasive measurement of the arterial pulse. Each method has unique strengths and weaknesses and relative comparison is limited by the absence of a widely accepted “gold standard” measurement. CO can also be affected by the phase of respiration with intra-thoracic pressure changes influencing diastolic filling and therefore CO. This is important especially during mechanical ventilation, and CO should therefore be measured at a defined phase of the respiratory cycle (typically end-expiration).
The Fick Principle
The Fick principle was first described by Adolph Fick in 1870 and assumes that the rate at which oxygen is consumed is a function of the rate of blood flows and the rate of oxygen pick up by the red blood cells. The Fick principle involves calculating the oxygen consumed over a given period of time from measurement of the oxygen concentration of the venous blood and the arterial blood. CO can be calculated from these measurements:- VO2 consumption per minute using a spirometer (with the subject re-breathing air) and a CO2 absorber
- the oxygen content of blood taken from the pulmonary artery (representing mixed venous blood)
- the oxygen content of blood from a cannula in a peripheral artery (representing arterial blood)
VO2 = (CO x CA) - (CO x CV)
where CA = Oxygen concentration of arterial blood and CV = Oxygen concentration of venous blood. This allows us to say
CO = (VO2/CA - CV)*100
and therefore calculate CO. While considered to be the most accurate method for CO measurement Fick is invasive and requires time for the sample analysis, and accurate oxygen consumption samples are difficult to acquire. There have also been modifications to the Fick method where respiratory oxygen content is measured as part of a closed system and the consumed Oxygen calculated using an assumed oxygen consumption index which is then used to calculate CO. Other modifications use inert gas as tracers and measure the change in inspired and expired gas concentrations to calculate CO (Innacor, Innovision A/S, Denmark).
Dilution methods
This method was initially described using an indicator dye and assumes that the rate at which the indicator is diluted reflects the CO. The method measures the concentration of a dye at different points in the circulation, usually from an intravenous injection and then at a downstream sampling site, usually in a systemic artery. More specifically, the CO is equal to the quantity of indicator dye injected divided by the area under the dilution curve measured downstream (the Stewart (1897)-Hamilton (1932) equation):The trapezoid rule is often used as an approximation of this integral.
Pulmonary Artery Thermodilution (Trans-right-heart Thermodilution)
The indicator method was further developed with replacement of the indicator dye by heated or cooled fluid and temperature change measured at different sites in the circulation rather than dye concentration; this method is known as thermodilution. The pulmonary artery catheter (PAC), also known as the Swan-Ganz catheter, was introduced to clinical practice in 1970 and provides direct access to the right heart for thermodilution measurements.The PAC is balloon tipped and is inflated to occlude the pulmonary artery. The PAC thermodilution method involves injection of a small mount (10ml) of cold saline at a known temperature into the pulmonary artery and measuring the temperature a know distance away (6-10cm).
The CO can be calculated from the measured temperature curve (The “thermodilution curve”). High CO will change the temperature rapidly, and low CO will change the temperature slowly. Usually three or four repeated measures are averaged to improve accuracy. However it is complex to perform and there are many sources of inaccuracy in the method.[7][8] Modern catheters are fitted with a heating filament which intermittently heats and measures the thermodilution curve providing serial CO measurement.
PAC use is complicated by infection, Pulmonary artery rupture, cardiac tamponade, and air embolism. Recent studies suggest use of the PAC is both dangerous and expensive, and it may not improve patient survival or treatment.[4][5][6] PAC use is in decline as clinicians move to less invasive, more effective technologies for monitoring haemodynamics.
Doppler Ultrasound Method
This method uses ultrasound and the Doppler effect to measure CO. The blood velocity through the heart causes a 'Doppler shift' in the frequency of the returning ultrasound waves. This Doppler shift can then be used to calculate flow velocity and volume and effectively CO using the following equations:- CO = SV x HR
- SV = vti x CSA
- CSA = flow cross sectional area from πd²/4
- d = valve diameter
- vti = the velocity time integral of the trace of the Doppler flow profile
Echocardiography
Echocardiography uses a conventional ultrasound machine and a combined two dimensional (2D) and Doppler approach to measure CO. 2D measurement of the diameter (d) of the aortic annulus allows calculation of the flow CSA which is then multiplied by the vti of the Doppler flow profile across the aortic valve to determine the flow volume or SV. Multiplying SV by HR produces CO. Echocardiographic measurement of flow volume is clinically well established and of proven accuracy but requires training and skill, and may be time consuming to perform effectively. The 2D measurement of the aortic valve diameter is challenging and associated with significant error, while measurement of the pulmonary valve to calculate right sided CO is even more difficult.Transcutaneous Doppler: USCOM
An Ultrasonic Cardiac Output Monitor (USCOM) (Uscom Ltd, Sydney, Australia) uses Continuous Wave Doppler (CW) to measure the Doppler flow profile vti, as in echocardiography, but uses anthropometry to calculate aortic and pulmonary valve diameters so both the right and left sided CO can be measured. Real time Automatic tracing of the Doppler flow profile allows for beat to beat right and left sided CO measurement. Importantly this single method can be used in neonates, children and adults for low and high CO measurement.Transoesophageal Doppler: TOD
Transoesophageal Doppler (TOD), also known as esophageal Doppler monitor (EDM), supports a CW sensor on the end of a probe which can be introduced via the mouth or nose and positioned in the oesophagus so the Doppler beam aligns with the descending thoracic aorta (DTA) at a known angle. Because the transducer is close to the blood flow the signal is clear, however the alignment, and thus reliable signal, can often be difficult to maintain during respiration and patient movement. This method has good validation, particularly for measuring changes in blood flow, but is limited in that it only measures the DTA flow and not true CO and is therefore influenced by non-linear changes in CO and SVR. Additionally this method requires patient sedation and is accepted for use only in adults and large children.Pulse Pressure Methods
Pulse Pressure (PP) methods measure the pressure in the arteries over time to derive a waveform and use this information to calculate cardiac performance. The problem is that any measure from the artery includes the changes in pressure associated with changes in arterial function.Physiologic or therapeutic changes in vessel diameter will be assumed to reflect changes in CO. Put simply PP methods measure the combined performance of the heart and the vessels thus limiting the application of PP methods for measurement of CO. This can be partially compensated for by intermittent calibration of the waveform to another CO measurement method and then monitoring the PP waveform. Ideally the PP waveform should be calibrated beat to beat.
There are invasive and non-invasive methods of measuring PP:
Non-invasive PP – Sphygmomanometry and Tonometry
The sphygmomanometer or cuff blood pressure device was introduced to clinical practice in 1903 allowing non-invasive measurements of blood pressure and providing the common PP waveform values of peak systolic and diastolic pressure which can be used to calculate mean arterial pressure (MAP). The pressure in the arteries, measured by sphygmomanometry, is often used as a guide to the function of the heart. Put simply, the pressure in the heart is conducted to the arteries, so the arterial pressure approximately reflects the function of the heart or the CO.- The pressure in the heart rises as blood is forced into the aorta
- The more stretched the aorta, the greater the pulse pressure (PP)
- In healthy young subjects, each additional 2 ml of blood results in a 1 mmHg rise in pressure
- Therefore:
- SV = 2 ml × Pulse Pressure
- CO = 2 ml × Pulse Pressure × HR
By resting a more sophisticated pressure sensing device, a tonometer, against the skin surface and sensing the pulsatile artery, continuous PP wave forms can be acquired non-invasively and analysis made of these pressure signals. Unfortunately the heart and vessels can function independently and sometimes paradoxically so that changes in the PP may both reflect and mask changes in CO. So these measures represent combined cardiac and vascular function only. Another similar system that uses the arterial pulse is the pressure recording analytical method (PRAM).
Invasive PP
Invasive PP involves inserting a manometer (pressure sensor) into an artery, usually the radial or femoral artery and continuously measuring the PP waveform. This is usually done by connecting the catheter to a signal processing and display device. The PP waveform can then be analysed to provide measurements of cardiovascular performance. Changes in vascular function or the position of the catheter tip will affect the accuracy of the readings. Invasive PP measurements can be calibrated or uncalibrated.Calibrated PP – PiCCO, LiDCO
PiCCO (PULSION Medical Systems AG, Munich, Germany) and PulseCO (LiDCO Ltd, London, England) generate continuous CO by analysis of the arterial PP waveform. In both cases, an independent technique is required to provide calibration of the continuous CO analysis, as arterial PP analysis cannot account for unmeasured variables such as the changing compliance of the vascular bed. Recalibration is recommended after changes in patient position, therapy or condition.In the case of PiCCO, transpulmonary thermodilution is used as the calibrating technique. Transpulmonary thermodilution uses the Stewart-Hamilton principle, but measures temperatures changes from central venous line to a central arterial line (i.e. femoral or axillary) arterial line. The CO derived from this cold-saline thermodilution is used to calibrate the arterial PP contour, which can then provide continuous CO monitoring. The PiCCO algorithm is dependent on blood pressure waveform morphology (i.e. mathematical analysis of the PP waveform) and calculates continuous CO as described by Wesseling and co-workers.[9] Transpulmonary thermodilution spans right heart, pulmonary circulation and left heart; this allows further mathematical analysis of the thermodilution curve, giving measurements of cardiac filling volumes (GEDV), intrathoracic blood volume, and extravascular lung water. While transpulmonary thermodilution allows for less invasive CO calibration, the method is also less accurate than PA thermodilution and still requires a central venous and arterial line with the attendant infection risks.
In the case of LiDCO, the independent calibration technique is lithium dilution, again using the Stewart-Hamilton principle. Lithium dilution uses a peripheral vein to a peripheral arterial line; however, it does not provide information on cardiac filling volumes and extravascular lung water. Calibration measurements cannot be performed too frequently, and can be subject to error in the presence of certain muscle relaxants. The PulseCO algorithm used by LiDCO is based on pulse power derivation and is not dependent on waveform morphology.
This method requires recalibration if the patient moves or therapy to change the vessel tone (vaso-active therapy) is introduced. Additionally the safe storage and regulatory control of the Lithium Chloride may be problematic.
Uncalibrated PP - FloTrac
This technology involves inserting a manometer tipped arterial catheter into the mid flow portion of an artery, usually radial or femoral, and then by time domain sampling converts the arterial PP to CO. While this method involves one less line than the calibrated PP CO systems, it remains un-calibrated and so is only measuring arterial PP invasively. While it estimates upstream CO, any independent changes in CO and SVR cannot be detected by this method. This method has yet to be extensively evaluated, but early studies suggest that it may be useful in stable, normal subjects.Impedance cardiography
Impedance cardiography (ICG) is a method which calculates CO from the measurement of changes in impedance across the chest over the cardiac cycle. Lower impedance indicates greater the intrathoracic fluid volume, and as the only fluid volume which changes beat to beat within the thorax is the blood, the change in impedance can be used to calculate the SV and, combined with HR, the CO. This technique has progressed clinically (often called BioZ, i.e. biologic impedance, as promoted by the leading manufacturer in the US) and allows non-invasive estimations of CO and total peripheral resistance using only 4 paired skin electrodes.While the method is desirably non-invasive and inexpensive, it has not achieved the reliability and reproducibility required of a useful clinical tool, and the evolution of algorithms to convert impedance signals to CO across a variety of outputs and in a variety of diseases continues.
Magnetic Resonance Imaging
Velocity encoded phase contrast Magnetic Resonance Imaging (MRI)[10] is the most accurate technique for measuring flow in large vessels in mammals. MRI flow measurements have been shown to be highly accurate compared to measurements with a beaker and timer[11], and less variable than both the Fick principle[12] and thermodilution[13].Velocity encoded MRI is based on detection of changes in the phase of proton precession. These changes are proportional to the velocity of the movement of those protons through a magnetic field with a known gradient. When using velocity encoded MRI, the result of the MRI scan is two sets of images for each time point in the cardiac cycle. One is an anatomical image and the other is an image where the signal intensity in each pixel is directly proportional to the through-plane velocity. The average velocity in a vessel, i.e. the aorta or the pulmonary artery, is hence quantified by measuring the average signal intensity of the pixels in the cross section of the vessel, and then multiplying by a known constant. The flow is calculated by multiplying the mean velocity by the cross-sectional area of the vessel. This flow data can be used to graph flow versus time. The area under the flow versus time curve for one cardiac cycle is the stroke volume. The length of the cardiac cycle is known and determines heart rate, and thereby CO can be calculated as the product of stroke volume and heart rate. MRI is typically used to quantify the flow over one cardiac cycle as the average of several heart beats, but it is also possible quantify the stroke volume in real time on a beat-for-beat basis[14].
While MRI is an important research tool for accurately measuring CO, it is currently not clinically used for hemodynamic monitoring in the emergency or intensive care setting. Cardiac output measurement by MRI is currently routinely used as a part of clinical cardiac MRI examinations[15].
Cardiac Output and Vascular Resistance
The vascular beds are a dynamic and connected part of the circulatory system against which the heart must pump to transport the blood. CO is influenced by the resistance of the vascular bed against which the heart is pumping. For the right heart this is the pulmonary vascular bed, creating Pulmonary Vascular Resistance (PVR), while for the systemic circulation this is the systemic vascular bed, creating Systemic Vascular Resistance (SVR). The vessels actively change diameter under the influence of physiology or therapy, vasoconstrictors decrease vessel diameter and increase resistance, while vasodilators increase vessel diameter and decrease resistance. Put simply increasing resistance decreases CO, and conversely decreased resistance increases CO.This can be explained mathematically:
By simplifying D'arcy's Law, we get the equation that
- Flow = Pressure/Resistance
When applied to the circulatory system, we get:
- CO = (MAP – RAP)/TPR
Where MAP = Mean Aortic (or Arterial) Blood Pressure in mmHg,
- RAP = Mean Right Atrial Pressure in mmHg and
However, as MAP>>RAP, and RAP is approximately 0, this can be simplified to:
- CO ≈ MAP/TPR
Physiologists will often re-arrange this equation, making MAP the subject, to study the body's responses.
As has already been stated, CO is also the product of the heart rate (HR) and the stroke volume (SV), which allows us to say:
- CO ≈ (HR x SV) ≈ MAP / TPR
Cardiac Output and Respiration
CO is affected by the phase of respiration with intra-thoracic pressure changes influencing diastolic heart filling and therefore CO. Breathing in reduces intra-thoracic pressure, filling the heart and increasing CO, while breathing out increases intra-thoracic pressure, reduces heart filing and CO. This respiratory response is called stroke volume variation and can be used as an indicator of cardiovascular health and disease. These respiratory changes are important, particularly during mechanical ventilation, and CO should therefore be measured at a defined phase of the respiratory cycle, usually end-expiration.External links
- Hemodynamics training for Junior Medical Staff
- The Gross Physiology of the Cardiovascular System
- The Determinants of Cardiac Output (online video)
References
1. ^ Berne RM, Levy MN. Cardiovascular physiology. 7th Ed Mosby 1997
2. ^ Rowell LB. Human Cardiovascular Control. Oxford University press 1993
3. ^ Braunwald E (Editor). Heart Disease: A Textbook of Cardiovascular Medicine. 5th Ed. W.B.Saunders 1997
4. ^ Stevenson LW and the ESCAPE investigators and ESCAPE coordinators. Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness. J Am Med Ass 2005;294:1625-1633
5. ^ Shah MR, Hasselblad V, Stevenson LW, Binanay C, O’Connor CM, Sopko G, Califf RM. Impacts of the Pulmonary Artery Catheter in Critically Ill Patients: Meta-analysis of Randomized Trials. J Am Med Ass 2005;294:1634-1670
6. ^ Hall JB. Searching for Evidence to Support Pulmonary Artery Catheter Use in Critically Ill Patients. J Am Med Ass 2005;294:1693-1694
7. ^ Iberti TJ, Fischer EP, Leibowitz AB, Panacek EA, Silverstein JH, Albertson TE. Pulmonary Artery Catheter Study Group. A Multicenter Study of Physicians’ Knowledge of the Pulmonary Artery Catheter. JAMA 1990;264:2928-2932
8. ^ Johnston IG, Jane R, Fraser JF, Kruger P, Hickling K. Survey of intensive care nurses’ knowledge relating to the pulmonary artery catheter. Anaesth Intensive Care 2004;32:564-568
9. ^ Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ. Compuation of aortic flow pressure in humans by using a nonlinear, three element model. J App Physiol 1993;74:2566-73
10. ^ Arheden H, Stahlberg F. Blood flow measurements. In: MRI and CT of the Cardiovascular System, 2nd edition, Editors: Higgins CB & de Roos A 2006:71-90.
11. ^ Arheden H, et al, Radiology, 1999.
12. ^ Razavi R, et al, Lancet, 2003.
13. ^ Kuehne T, et al, Heart, 2005.
14. ^ Petzina R, et al, J Thorac Cardiovasc Surg, 2007.
15. ^ Pennell DJ, et al, Eur Heart J, 2004.
2. ^ Rowell LB. Human Cardiovascular Control. Oxford University press 1993
3. ^ Braunwald E (Editor). Heart Disease: A Textbook of Cardiovascular Medicine. 5th Ed. W.B.Saunders 1997
4. ^ Stevenson LW and the ESCAPE investigators and ESCAPE coordinators. Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness. J Am Med Ass 2005;294:1625-1633
5. ^ Shah MR, Hasselblad V, Stevenson LW, Binanay C, O’Connor CM, Sopko G, Califf RM. Impacts of the Pulmonary Artery Catheter in Critically Ill Patients: Meta-analysis of Randomized Trials. J Am Med Ass 2005;294:1634-1670
6. ^ Hall JB. Searching for Evidence to Support Pulmonary Artery Catheter Use in Critically Ill Patients. J Am Med Ass 2005;294:1693-1694
7. ^ Iberti TJ, Fischer EP, Leibowitz AB, Panacek EA, Silverstein JH, Albertson TE. Pulmonary Artery Catheter Study Group. A Multicenter Study of Physicians’ Knowledge of the Pulmonary Artery Catheter. JAMA 1990;264:2928-2932
8. ^ Johnston IG, Jane R, Fraser JF, Kruger P, Hickling K. Survey of intensive care nurses’ knowledge relating to the pulmonary artery catheter. Anaesth Intensive Care 2004;32:564-568
9. ^ Wesseling KH, Jansen JRC, Settels JJ, Schreuder JJ. Compuation of aortic flow pressure in humans by using a nonlinear, three element model. J App Physiol 1993;74:2566-73
10. ^ Arheden H, Stahlberg F. Blood flow measurements. In: MRI and CT of the Cardiovascular System, 2nd edition, Editors: Higgins CB & de Roos A 2006:71-90.
11. ^ Arheden H, et al, Radiology, 1999.
12. ^ Razavi R, et al, Lancet, 2003.
13. ^ Kuehne T, et al, Heart, 2005.
14. ^ Petzina R, et al, J Thorac Cardiovasc Surg, 2007.
15. ^ Pennell DJ, et al, Eur Heart J, 2004.
heart is a muscular organ responsible for pumping blood through the blood vessels by repeated, rhythmic contractions, or a similar structure in the annelids, mollusks, and arthropods.
..... Click the link for more information.
..... Click the link for more information.
In the heart, a ventricle is a heart chamber which collects blood from an atrium (another heart chamber that is smaller than a ventricle) and pumps it out of the heart.
..... Click the link for more information.
..... Click the link for more information.
Stroke volume is the amount of blood pumped by the left ventricle of the heart in one contraction.
The stroke volume is not all of the blood contained in the left ventricle. The heart does not pump all the blood out of the ventricle.
..... Click the link for more information.
The stroke volume is not all of the blood contained in the left ventricle. The heart does not pump all the blood out of the ventricle.
..... Click the link for more information.
Heart rate is a term used to describe the frequency of the cardiac cycle. It is considered one of the four vital signs. Usually it is calculated as the number of contractions (heart beats) of the heart in one minute and expressed as "beats per minute" (bpm).
..... Click the link for more information.
..... Click the link for more information.
Cardiac index (CI) is a vasodynamic parameter that relates the cardiac output (CO) to body surface area (BSA), thus relating heart performance to the size of the individual. The unit of measurement is litres per minute per square metre (l/min/m^2).
..... Click the link for more information.
..... Click the link for more information.
Fick principle is a technique for measuring cardiac output.
..... Click the link for more information.
Variables
The following variables are measured:[1]- VO2 consumption per minute using a spirometer (with the subject re-breathing air) and a CO2 absorber
..... Click the link for more information.
Ultrasound is a cyclic sound pressure with a frequency greater than the upper limit of human hearing, this limit being approximately 20 kilohertz (20,000 hertz).
..... Click the link for more information.
Ability to hear ultrasound
..... Click the link for more information.
Doppler effect, named after Christian Doppler, is the change in frequency and wavelength of a wave as perceived by an observer moving relative to the source of the waves. For waves that propagate in a wave medium, such as sound waves, the velocity of the observer and of the source
..... Click the link for more information.
..... Click the link for more information.
Impedance cardiography is a hemorheology technique of using sensors to detect the properties of the blood flow in the Thorax.
..... Click the link for more information.
Introduction
Impedance cardiography (ICG), also referred to as thoracic electrical bioimpedance (TEB) and electrical impedance plethysmography..... Click the link for more information.
Electrical impedance, or simply impedance, describes a measure of opposition to a sinusoidal alternating current (AC). Electrical impedance extends the concept of resistance to AC circuits, describing not only the relative magnitudes of the voltage and current, but also the
..... Click the link for more information.
..... Click the link for more information.
Precession refers to a change in the direction of the axis of a rotating object. In physics, there are two types of precession, torque-free and torque-induced, the latter being discussed here in more detail.
..... Click the link for more information.
..... Click the link for more information.
The aorta (generally pronounced [eɪˈɔːtə] or "ay-orta") is the largest artery in the human body, originating from the left ventricle of the heart and bringing oxygenated blood to all parts of the body in the systemic circulation.
..... Click the link for more information.
..... Click the link for more information.
The pulmonary arteries carry blood from the heart to the lungs. They are the only arteries (other than umbilical arteries in the fetus) that carry deoxygenated blood.
In the human heart, the pulmonary trunk (pulmonary artery or main pulmonary artery
..... Click the link for more information.
In the human heart, the pulmonary trunk (pulmonary artery or main pulmonary artery
..... Click the link for more information.
pixel (short for picture element, using the common abbreviation "pix" for "pictures") is a single point in a graphic image. Each such information element is not really a dot, nor a square, but an abstract sample.
..... Click the link for more information.
..... Click the link for more information.
Cardiac cycle is the term referring to all or any of the events related to the flow of blood that occur from the beginning of one heartbeat to the beginning of the next.[1] The frequency of the cardiac cycle is the heart rate.
..... Click the link for more information.
..... Click the link for more information.
Stroke volume is the amount of blood pumped by the left ventricle of the heart in one contraction.
The stroke volume is not all of the blood contained in the left ventricle. The heart does not pump all the blood out of the ventricle.
..... Click the link for more information.
The stroke volume is not all of the blood contained in the left ventricle. The heart does not pump all the blood out of the ventricle.
..... Click the link for more information.
Heart rate is a term used to describe the frequency of the cardiac cycle. It is considered one of the four vital signs. Usually it is calculated as the number of contractions (heart beats) of the heart in one minute and expressed as "beats per minute" (bpm).
..... Click the link for more information.
..... Click the link for more information.
Circulatory System is a psychedelic rock musical ensemble formed by musician/painter Will Cullen Hart, and featuring Hannah Jones, Derek Almstead, Peter Erchick, John Fernandes, and Heather McIntosh.
..... Click the link for more information.
..... Click the link for more information.
Human physiology is the science of the mechanical, physical, and biochemical functions of humans in good health, their organs, and the cells of which they are composed. The principal level of focus of physiology is at the level of organs and systems.
..... Click the link for more information.
..... Click the link for more information.
Cardiovascular physiology is the study of the circulatory system. More specifically, it addresses the physiology of the heart ("cardio") and blood vessels ("vascular").
..... Click the link for more information.
..... Click the link for more information.
preload is the pressure stretching the ventricle of the heart, after passive filling and atrial contraction. If the chamber is not mentioned, it is usually assumed to be the left ventricle.
..... Click the link for more information.
..... Click the link for more information.
afterload is used to mean the tension produced by a chamber of the heart in order to contract. If the chamber is not mentioned, it is usually assumed to be the left ventricle. However, the strict definition of the term relates to the properties of a single cardiac myocyte.
..... Click the link for more information.
..... Click the link for more information.
End-systolic volume (ESV) is the volume of blood in the ventricles just after systole. The amount of blood in the ventricle at the end of the cardiac ejection period and immediately preceding the beginning of ventricular relaxation; a measurement of the adequacy of cardiac
..... Click the link for more information.
..... Click the link for more information.
In cardiovascular physiology, end-diastolic volume (EDV) is the volume of blood in a ventricle at the end of filling (diastole). Because greater EDVs cause greater distention of the ventricle, EDV is often used synonymously with preload
..... Click the link for more information.
..... Click the link for more information.
The Frank-Starling law of the heart (also known as Starling's law or the Frank-Starling mechanism) states that the more the ventricle is filled with blood during diastole (end-diastolic volume), the greater the volume of ejected blood will be during the resulting
..... Click the link for more information.
..... Click the link for more information.
Wiggers diagram is a standard diagram used in cardiac physiology.
The X axis is used to plot time, while the Y axis contains all of the following on a single grid:
..... Click the link for more information.
The X axis is used to plot time, while the Y axis contains all of the following on a single grid:
- Blood pressure
..... Click the link for more information.
A pressure volume diagram (or P-V diagram, or volume-pressure loop)[1]) is used to describe a thermal cycle involving the following two variables:
..... Click the link for more information.
- Volume (on the X axis)
- Pressure (on the Y axis)
..... Click the link for more information.
Chronotropic effects (from chrono-, meaning time) are those that change the heart rate.
Chronotropic drugs may change the heart rate by affecting the nerves controlling the heart, or by changing the rhythm produced by the sinoatrial node.
..... Click the link for more information.
A dromotropic agent is one which affects the conduction velocity of the AV node, and subsequently the rate of electrical impulses in the heart.[1][2]
Agents that are dromotropic are often (but not always) inotropic and chronotropic.
..... Click the link for more information.
Agents that are dromotropic are often (but not always) inotropic and chronotropic.
..... Click the link for more information.
An inotrope (IPA: [ˈaɪnətrop]) is an agent which increases or decreases the force or energy of muscular contractions. Negatively inotropic agents weaken the force of muscular contractions.
..... Click the link for more information.
..... Click the link for more information.
This article is copied from an article on Wikipedia.org - the free encyclopedia created and edited by online user community. The text was not checked or edited by anyone on our staff. Although the vast majority of the wikipedia encyclopedia articles provide accurate and timely information please do not assume the accuracy of any particular article. This article is distributed under the terms of GNU Free Documentation License.
Herod_Archelaus
