An alternating current (AC) is an electrical current whose magnitude and direction vary cyclically, as opposed to direct current, whose direction remains constant. The usual waveform of an AC power circuit is a sine wave, as this results in the most efficient transmission of energy. However in certain applications different waveforms are used, such as triangular or square waves.

Used generically, AC refers to the form in which electricity is delivered to businesses and residences. However, audio and radio signals carried on electrical wire are also examples of alternating current. In these applications, an important goal is often the recovery of information encoded (or modulated) onto the AC signal.

History

William Stanley, Jr. designed one of the first practical devices to transfer AC power efficiently between isolated circuits. Using pairs of coils wound on a common iron core, his design, called an induction coil, was an early precursor of the modern transformer. The system used today was devised in the late nineteenth century, largely by Nikola Tesla. Contributions were also made by George Westinghouse, Lucien Gaulard, John Dixon Gibbs, Carl Wilhelm Siemens and Oliver Shallenger. AC systems overcame the limitations of the direct current system used by Thomas Edison to distribute electricity efficiently over long distances.

The first modern commercial power plant using three-phase alternating current was at the Mill Creek hydroelectric plant near Redlands, California in 1893. Its designer was Almirian Decker, a brilliant young engineer. Decker's innovative design incorporated 10,000 volt three phase transmission and established the standards for the complete system of generation, transmission and motors used today. And through the use of alternating current, Charles Proteus Steinmetz of General Electric was able to solve many of the problems associated with electricity generation and transmission.

Alternating current circuit theory evolved rapidly in the latter part of the 19th and early 20th century. Notable contributors to the theoretical basis of alternating current calculations include Charles Steinmetz, James Clerk Maxwell, Oliver Heaviside, and many others. Calculations in unbalanced three-phase systems were simplified by the symmetrical components methods discussed by Charles Legeyt Fortescue in 1918.

Transmission, distribution, and domestic power supply



AC voltage can be stepped up or down by a transformer to a different voltage. Modern high-voltage, direct-current electric power transmission systems contrast with the more common alternating-current systems as a means for the bulk transmission of electrical power over long distances. However, these tend to be more expensive and less efficient than transformers, and did not exist when Edison, Westinghouse and Tesla were designing their power systems.

Use of a higher voltage leads to significantly more efficient transmission of power. The power losses in a conductor are a product of the square of the current and the resistance of the conductor, described by the formula . This means that when transmitting a fixed power on a given wire, if the current is doubled, the power loss will be four times greater. Since the power transmitted is equal to the product of the current, the voltage and the cosine of the phase difference φ (), the same amount of power can be transmitted with a lower current by increasing the voltage. Therefore it is advantageous when transmitting large amounts of power to distribute the power with high voltages (often hundreds of kilovolts). However, high voltages also have disadvantages, the main ones being the increased insulation required, and generally increased difficulty in their safe handling. In a power plant, power is generated at a convenient voltage for the design of a generator, and then stepped up to a high voltage for transmission. Near the loads, the transmission voltage is stepped down to the voltages used by equipment. Consumer voltages vary depending on the country and size of load, but generally motors and lighting are built to use up to a few hundred volts between phases.

The utilization voltage delivered to equipment such as lighting and motor loads is standardized, with an allowable range of voltage over which equipment is expected to operate. Standard power utilization voltages and percentage tolerance vary in the different mains power systems found in the world.

Three-phase electrical generation is very common. Three separate coils in the generator stator are physically offset by an angle of 120° to each other. Three current waveforms are produced that are equal in magnitude and 120° out of phase to each other.

If the load on a three-phase system is balanced equally among the phases, no current flows through the neutral point. Even in the worst-case unbalanced (linear) load, the neutral current will not exceed the highest of the phase currents. For three-phase at low (normal mains) voltages a four-wire system is normally used. When stepping down three-phase, a transformer with a Delta primary and a Star secondary is often used so there is no need for a neutral on the supply side.

For smaller customers (just how small varies by country and age of the installation) only a single phase and the neutral or two phases and the neutral are taken to the property. For larger installations all three phases and the neutral are taken to the main distribution panel. From the three-phase main panel, both single and three-phase circuits may lead off.

Three-wire single phase systems, with a single centre-tapped transformer giving two live conductors, is a common distribution scheme for residential and small commercial buildings in North America. This arrangement is sometimes incorrectly referred to as "two phase". A similar method is used for a different reason on construction sites in the UK. Small power tools and lighting are supposed to be supplied by a local center-tapped transformer with a voltage of 55V between each power conductor and the earth. This significantly reduces the risk of electric shock in the event that one of the live conductors becomes exposed through an equipment fault whilst still allowing a reasonable voltage for running the tools.

A third wire, called the bond wire, is often connected between non-current carrying metal enclosures and earth ground. This conductor provides protection from electrical shock due to accidental contact of circuit conductors with the metal chassis of portable appliances and tools. Bonding all non-current carrying metal parts into one complete system ensures there is always a low impedance path to ground sufficient to carry any fault current for as long as it takes for the system to clear the fault. This low impedance path allows the maximum amount of fault current to flow, causing the overcurrent protection device (Breakers, fuses) to trip or burn out as quickly as possible, returning the electrical system to a safe state. All bond wires are bonded to ground at the main service panel, as is the Neutral/Identified Conductor if present.

AC power supply frequencies

The frequency of the electrical system varies by country; most electric power is generated at either 50 or 60 Hz. See List of countries with mains power plugs, voltages and frequencies. Some countries have a mixture of 50 Hz and 60 Hz supplies, notably Japan.

A low frequency eases the design of low speed electric motors, particularly for hoisting, crushing and rolling applications, and commutator-type traction motors for applications such as railways, but also causes a noticeable flicker in incandescent lighting and objectionable flicker of fluorescent lamps. 16⅔ Hz power (one third of the mains frequency) is still used in some European rail systems, such as in Austria, Germany, Norway, Sweden and Switzerland.

The use of lower frequencies also provided the advantage of lower impedance losses, which are proportional to frequency. It was this argument that resulted in the use of 25 Hz in the initial generation installations at Niagara Falls, in anticipation of long-distance transmission to Toronto. Improvements in transmission technology later made it feasible to use 60 Hz as an acceptable, and more desirable, frequency. The conversion lasted into the 1950s, costing Ontario Hydro dearly as it replaced all clocks, refrigerators and other motor-driven appliances in the Toronto area.

Off-shore, textile industry, marine, computer mainframe, aircraft, and spacecraft applications sometimes use 400 Hz, for benefits of reduced weight of apparatus or higher motor speeds.

Effects at high frequencies

A direct, constant current flows uniformly throughout the cross-section of the (uniform) wire that carries it. With alternating current of any frequency, the current is forced towards the outer surface of the wire, and away from the center. This is due to the fact that an electric charge which accelerates (as is the case of an alternating current) radiates electromagnetic waves, and materials of high conductivity (the metal which makes up the wire) do not allow propagation of electromagnetic waves. This phenomenon is called skin effect.

At very high frequencies the current no longer flows in the wire, but effectively flows on the surface of the wire, within a thickness of a few skin depths. The skin depth is the thickness at which the current density is reduced by 63%. Even at relatively low frequencies used for high power transmission (50–60 Hz), non-uniform distribution of current still occurs in sufficiently thick conductors. For example, the skin depth of a copper conductor is approximately 8.57 mm at 60 Hz, so high current conductors are usually hollow to reduce their mass and cost.

Since the current tends to flow in the periphery of conductors, the effective cross-section of the conductor is reduced. This increases the effective AC resistance of the conductor, since resistance is inversely proportional to the cross-sectional area in which the current actually flows. The AC resistance often is many times higher than the DC resistance, causing a much higher energy loss due to ohmic heating (also called I2R loss).

Techniques for reducing AC resistance

For low to medium frequencies, conductors can be divided into stranded wires, each insulated from one other, and the individual strands specially arranged to change their relative position within the conductor bundle. Wire constructed using this technique is called Litz wire. This measure helps to partially mitigate skin effect by forcing more equal current flow throughout the total cross section of the stranded conductors. Litz wire is used for making high Q inductors, reducing losses in flexible conductors carrying very high currents at power frequencies, and in the windings of devices carrying higher radio frequency current (up to hundreds of kilohertz), such as switch-mode power supplies and radio frequency transformers.

Techniques for reducing radiation loss

As written above, an alternating current is made of electric charge under periodic acceleration, which causes radiation of electromagnetic waves. Energy that is radiated represents a loss. Depending on the frequency, different techniques are used to minimize the loss due to radiation.

Twisted pairs

At frequencies up to about 1 GHz, wires are paired together in cabling to form a twisted pair in order to reduce losses due to electromagnetic radiation and inductive coupling. A twisted pair must be used with a balanced signalling system, where the two wires carry equal but opposite currents. The result is that each wire in the twisted pair radiates a signal that is effectively cancelled by the other wire, resulting in almost no electromagnetic radiation.

Coaxial cables

At frequencies above 1 GHz, unshielded wires of practical dimensions lose too much energy to radiation, so coaxial cables are used instead. A coaxial cable has a conductive wire inside a conductive tube. The current flowing on the inner conductor is equal and opposite to the current flowing on the inner surface of the outer tube. This causes the electromagnetic field to be completely contained within the tube, and (ideally) no energy is radiated or coupled outside the tube. Coaxial cables have acceptably small losses for frequencies up to about 20 GHz. For microwave frequencies greater than 20 GHz, the dielectric losses (due mainly to the dissipation factor of the dielectric layer which separates the inner wire from the outer tube) become too large, making waveguides a more efficient medium for transmitting energy.

Waveguides

Waveguides are similar to coax cables, as both consist of tubes, with the biggest difference being that the waveguide has no inner conductor. Waveguides can have any arbitrary cross section, but rectangular cross sections are the most common. With waveguides, the energy is no longer carried by an electric current, but by a guided electromagnetic field. Waveguides have dimensions comparable to the wavelength of the alternating current to be transmitted, so are only feasible at microwave frequencies.

Fiber optics

At frequencies greater than 200 GHz, waveguide dimensions become impractically small, and the ohmic losses in the waveguide walls become large. Instead, fiber optics, which are a form of dielectric waveguides, can be used. For such frequencies, the concepts of voltages and currents are no longer used.

Mathematics of AC voltages

Enlarge picture
A sine wave, over one cycle (360°). The dashed line represents the root mean square (RMS) value


Alternating currents are accompanied by alternating voltages. An AC voltage v can be described mathematically as a function of time by the following equation:

,


where
  • is the peak voltage (unit: volt),
  • is the angular frequency (unit: radians per second)
  • The angular frequency is related to the physical frequency, , which represents the number of oscillations per second (unit = hertz), by the equation .
  • is the time (unit: second).
The peak-to-peak value of an AC voltage is defined as the difference between its positive peak and its negative peak. Since the maximum value of is +1 and the minimum value is −1, an AC voltage swings between and . The peak-to-peak voltage, usually written as or , is therefore .

Power and root mean square

The relationship between voltage and power is:
where represents a load resistance


Rather than using instanteneous power, , it is more practical to use a time averaged power (where the averaging is performed over any integer number of cycles). Therefore, AC voltage is often expressed as a root mean square (RMS) value, written as , because


For a sinusoidal voltage:


For non-sinusoidal waveforms, the relationship between and is different

Example

To illustrate these concepts, consider a 240 V AC mains supply. It is so called because its RMS value is (at least nominally) 240 V. This means that the time-averaged power delivered is equivalent to the power delivered by a DC voltage of 240 Volts. To determine the peak voltage (amplitude), we can modify the above equation to:


For our 240 V AC, the peak voltage Vpeak is therefore , which is about 339 V. The peak-to-peak value of the 240 V AC is double that, at about 679 V.

Further reading

  • Willam A. Meyers, History and Reflections on the Way Things Were: Mill Creek Power Plant - Making History with AC, IEEE Power Engineering Review, February 1997, Pages 22-24

See also

External links

Electric current is the flow (movement) of electric charge. The SI unit of electric current is the ampere (A), which is equal to a flow of one coulomb of charge per second.

Definition

The amount of electric current (measured in amperes) through some surface, e.g.
..... Click the link for more information.


The magnitude of a mathematical object is its size: a property by which it can be larger or smaller than other objects of the same kind; in technical terms, an ordering of the class of objects to which
..... Click the link for more information.
Direct current (DC or "continuous current") is the constant flow of electric charge. This is typically in a conductor such as a wire, but can also be through semiconductors, insulators, or even through a vacuum as in electron or ion beams.
..... Click the link for more information.
Waveform means the shape and form of a signal such as a wave moving in a solid, liquid or gaseous medium.

In many cases the medium in which the wave is being propagated does not permit a direct visual image of the form.
..... Click the link for more information.
Real power (P)
  • Reactive power (Q)
  • Complex power (S) ; |S|, the modulus of complex power, is referred to as apparent power.
    ..... Click the link for more information.
  • sine wave or sinusoid is a function that occurs often in mathematics, physics, signal processing, electrical engineering, and many other fields. Its most basic form is:



    which describes a wavelike function of time (t) with
    ..... Click the link for more information.
    Electricity (from New Latin ēlectricus, "amberlike") is a general term for a variety of phenomena resulting from the presence and flow of electric charge. This includes many well-known physical phenomena such as lightning, electromagnetic fields and electric currents,
    ..... Click the link for more information.
    An audio frequency (abbreviation: AF), or audible frequency is characterized as a periodic vibration whose frequency is audible to the average human. While the range of frequencies that any individual can hear is largely related to environmental factors, the generally
    ..... Click the link for more information.
    Radio frequency, or RF, is a frequency or rate of oscillation within the range of about 3 Hz and 300 GHz. This range corresponds to frequency of alternating current electrical signals used to produce and detect radio waves.
    ..... Click the link for more information.
    A wire is a single, usually cylindrical, elongated strand of drawn metal. Wires are used to bear mechanical loads and to carry electricity and telecommunications signals . Standard sizes are determined by various wire gauges.
    ..... Click the link for more information.
    Information is the result of processing, gathering, manipulating and organizing data in a way that adds to the knowledge of the receiver. In other words, it is the context in which data is taken.
    ..... Click the link for more information.
    For the musical use of "modulation" as a change of key, see modulation (music).
    In telecommunications, modulation is the process of varying a periodic waveform, i.e.
    ..... Click the link for more information.
    William Stanley, Jr. (November 28, 1858–May 14, 1916) was an American physicist born in Brooklyn, New York. In his career, he obtained 129 patents covering a variety of electric devices.
    ..... Click the link for more information.
    An Induction coil or "spark coil" (archaically known as a Ruhmkorff coil) is a type of disruptive discharge coil. It is a passive electrical device used to produce high-voltage pulses from a low-voltage DC supply.
    ..... Click the link for more information.
    transformer is a device that transfers electrical energy from one circuit to another through inductively coupled wires. A changing current in the first circuit (the primary
    ..... Click the link for more information.
    Nikola Tesla
    Никола Тесл?


    I have harnessed the cosmic rays and caused them to operate a motive device.
    ..... Click the link for more information.
    George Westinghouse, Jr (15 October 1846–12 March 1914) was an American entrepreneur and engineer who invented the railroad air brake and was a pioneer of the electrical industry.
    ..... Click the link for more information.
    Lucien Gaulard (1850 - November 26, 1888) invented devices for the transmission of alternating current electrical energy. Gaulard was born in Paris, France.

    A power transformer developed by Gaulard of France and John Dixon Gibbs of England was demonstrated in London, and
    ..... Click the link for more information.
    Carl Wilhelm Siemens (en: Charles William Siemens, known as Sir William Siemens) (4 April, 1823 – 19 November, 1883) was a German engineer.
    ..... Click the link for more information.
    Direct current (DC or "continuous current") is the constant flow of electric charge. This is typically in a conductor such as a wire, but can also be through semiconductors, insulators, or even through a vacuum as in electron or ion beams.
    ..... Click the link for more information.
    Thomas Alva Edison (February 11 1847 – October 18 1931) was an American inventor and businessman who developed many devices that greatly influenced life around the world, including the phonograph and a long lasting light bulb.
    ..... Click the link for more information.
    City of Redlands
    Nickname: Jewel of the Inland Empire
    Location of Redlands in California
    Coordinates:
    Country United States
    State California
    ..... Click the link for more information.
    Charles Proteus Steinmetz (April 9, 1865 – October 26, 1923) was an American mathematician and electrical engineer. He fostered the development of alternating current that made possible the expansion of the electric power industry in the United States, formulating
    ..... Click the link for more information.
    General Electric Co.

    Public (NYSE:  GE )
    Founded 1878 in Menlo Park, New Jersey
    Founder Thomas Alva Edison
    Headquarters Fairfield, Connecticut,[1] USA

    Key people Jeff Immelt, Chairman & CEO
    Keith Sherin, Vice Chairman, CFO
    ..... Click the link for more information.
    Electricity generation is the first process in the delivery of electricity to consumers. The other processes are electric power transmission and electricity distribution which are normally carried out by the electrical power industry.
    ..... Click the link for more information.
    Charles Proteus Steinmetz (April 9, 1865 – October 26, 1923) was an American mathematician and electrical engineer. He fostered the development of alternating current that made possible the expansion of the electric power industry in the United States, formulating
    ..... Click the link for more information.
    James Clerk Maxwell

    James Clerk Maxwell
    Born May 13 1831(1831--)
    Edinburgh, Scotland
    Died November 5 1879 (aged 48)
    ..... Click the link for more information.
    Oliver Heaviside

    Portrait of Oliver Heaviside (1850-1925) by Frances Hodge
    Born May 18 1850(1850--)
    Camden Town, London, England
    ..... Click the link for more information.
    In electrical engineering, the method of Symmetrical components is used to simplify analysis of unbalanced three phase power systems.

    Charles Legeyt Fortescue in a paper presented in 1918 (
    ..... Click the link for more information.
    Charles LeGeyt Fortescue (1876-1936) was born in York Factory, in what is now Manitoba where the Hayes River enters Hudson Bay. He was the son of a Hudson's Bay Company fur trading factor and was among the first graduates of the Queen's University electrical engineering program in
    ..... Click the link for more information.


    This article is copied from an article on Wikipedia.org - the free encyclopedia created and edited by online user community. The text was not checked or edited by anyone on our staff. Although the vast majority of the wikipedia encyclopedia articles provide accurate and timely information please do not assume the accuracy of any particular article. This article is distributed under the terms of GNU Free Documentation License.